Summit Microelectronics, Inc: Developer Support

Summit Microelectronics, Inc

Tech Support: Applications Note 32
SMS64 SIX-CHANNEL SUPPLY MONITOR AND SEQUENCING CONTROLLER - Windows GUI Users Guide and Configuration Register Descriptions




SPECIAL NOTE: The HTML version of the application note has been divided into multiple pages to follow the PDF version. You may click on a page number (below) to jump to another other page. You may also download/view the entire application note in PDF format [PDF format].

1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
Next -->

SMS64 SIX-CHANNEL SUPPLY MONITOR AND SEQUENCING CONTROLLER Windows GUI Users Guide and Configuration Register Descriptions

  PAGE 3    

 

Register R00, R01, R02, R03, R04, R05, - Bus-Side Under-Voltage Threshold

Registers 00, 01, 02, 03, 04 and 05 have similar functions. Their contents select the under-voltage or over-voltage threshold for the VCCA, VCCB, VCCC, VCCD, VCCE and VCCF inputs, respectively. The threshold for the trip point detector is programmable in 20mV increments, from 0.9V to 6.0V. Several example settings are shown in the table below:
 

Note 32 - Table 01
 
Note 32 - Figure 06

1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
Next -->


SUMMIT Microelectronics, Inc. reserves the right to make changes to the products contained in this publication in order to improve design, performance or reliability. SUMMIT Microelectronics, Inc. assumes no responsibility for the use of any circuits described herein, conveys no license under any patent or other right, and makes no representation that the circuits are free of patent infringement. Charts and schedules contained herein reflect representative operating parameters, and may vary depending upon a user's specific application. While the information in this publication has been carefully checked, SUMMIT Microelectronics, Inc. shall not be liable for any damages arising as a result of any error or omission.

SUMMIT Microelectronics, Inc. does not recommend the use of any of its products in life support or aviation applications where the failure or malfunction of the product can reasonably be expected to cause any failure of either system or to significantly affect their safety or effectiveness. Products are not authorized for use in such applications unless SUMMIT Microelectronics, Inc. receives written assurances, to its satisfaction, that: (a) the risk of injury or damage has been minimized; (b) the user assumes all such risks; and (c) potential liability of SUMMIT Microelectronics, Inc. is adequately protected under the circumstances.

Revision 1.1 - This document supersedes all previous versions and covers Status Tracking Codes up to 01 and Windows GUI revision 2.3.0 and later. Please check the Summit Microelectronics, Inc. web site at
www.summitmicro.com for data sheet updates.

 

Summit Microelectronics, Inc. Home Page

Summit Microelectronics, Inc. Developer Support: Applications Note Index

Copyright © 2002 SUMMIT MICROELECTRONICS, Inc.
Power Management for Communications™

I2C is a trademark of Philips Corporation
Online support by Montanesque Enterprises